Send to a Friend

Endurable Concrete Sealer™, Gloss

Endurable Concrete Sealer™, Gloss (12 oz)
SKU#: MP-ESAMPLEG-EA
Out of stock accepting backorders.
$43.75
Endurable Concrete Sealer™, Gloss (4.5 GL)
SKU#: ST-ESCG45-EA
In stock
$509.39
Endurable Concrete Sealer™, Gloss (9 GL)
SKU#: ST-ESCG9-EA
SKU UnavailableNo Longer in Stock
Out of stock
Endurable Concrete Sealer™, Gloss (GL)
SKU#: ST-ESCG-EA
In stock
$127.97

Product Highlights

Engineered with cutting-edge polyurethane technology, Endurable Concrete Sealer offers maximum penetration, durability, and chemical resistance! This versatile low-odor, low-VOC sealer can be used on both interior and exterior surfaces.
  • Gloss finish
  • Ideal for interior and exterior use
  • Excellent resistance to chemicals, scratches, & hot tire pickup
  • Low odor, low VOC
  • Coverage: 300–800 sq ft/gallon (depending on surface porosity)
Same-day Shipping
Industry's Best Guarantee
Equipment Service & Repair
Free Technical Support

Product Description

Cutting-Edge Polyurethane Technology Offers Maximum Penetration, Durability, and Chemical Resistance!

 

Excellent Durability
Endurable Concrete Sealer resists chemicals, scratches, hot tire pickup, and graffiti. This high-performance sealer is also 100% UV stable, ensuring it will not yellow or degrade in sunlight.

 

Whether you’re using it in a garage, public patio, or home interior, Endurable Concrete Sealer provides outstanding resistance to damage of all types, preserving the life and beauty of your concrete surfaces.

 

Sealed surfaces can last 5 to 10 years (depending on traffic and usage) before needing to be re-sealed.

 

Easy to Apply
Endurable Concrete Sealer can be applied via sprayer, T-bar microfiber applicator, or roller. Just two coats are all that is needed to achieve great results. After application, tools may be cleaned using soap and water.

 

Endurable Concrete Sealer has low VOC content and low odor, ensuring greater operator comfort during application and higher customer satisfaction during drying/curing times.

 

Fast Dry Times
Each coat of Endurable Concrete sealer typically dries in 45–180 minutes (for matte finish) or 3–6 hours (for gloss finish) depending on airflow and temperature.

 

Light traffic is possible after 8–24 hours, and heavy traffic is possible after 24–48 hours. The sealer will gain strength over the next few days after application and reach full cure at 7–10 days.

 

Excellent Versatility
Endurable Concrete Sealer can be used on both interior and exterior surfaces with great results. It provides the durable protection you need on commercial floors subject to heavy wheeled traffic, as well as the beauty you desire on residential countertops and walkways.

 

Endurable Concrete Sealer is ideal for use on the following concrete surfaces:

  • Garages
  • Driveways
  • Patios
  • Walkways
  • Countertops
  • Pool decks
  • Commercial Floors
  • As well as masonry, terrazzo, and natural stone

 

Usage

APPLICATION INSTRUCTIONS: FOR POLISHED CONCRETE, YOU MUST FOLLOW THE ARCHITECTURAL SPECS AVAILABLE ON THE DROP-DOWN MENU AT ENDURABLEPRODUCTS.COM.

FOR ALL OTHER APPLICATIONS, FOLLOW THE INSTRUCTIONS BELOW.

  1. For optimum results, open troweled concrete mechanically.
  2. Apply to dry, porous concrete.
  3. Mix Component 1 with Component 2, then mix with twice as much water as components.
  4. Use a mixing drill and paddle for minimum of 2 minutes.
    • Pot life is 45 to 90 minutes on matte and 90 to 180 minutes on gloss.
  5. Do not apply 2nd coat until 1st coat is completely dry.
    • Product may be applied via pump sprayer with a conical tip - .05 to .15 gpm at 40 psi, airless sprayer, or T-Bar micro-fiber applicator.
    • When applying over stain, it is recommended to spray the first coat to avoid movement of color residue.
    • Second coat MUST be applied via microfiber T-Bar applicator or low-speed buffer when dealing with smooth surface floors.
    • Second coat may be applied via sprayer on most exterior concrete.

PRODUCT SHOULD BE MIXED 1 TO 1 WITH WATER ON SECOND OR SUBSEQUENT COATS WHEN APPLYING OVER NON-POROUS OR SMOOTH SURFACES. DO NOT OVER-APPLY.

 

 

Coverage rates are typically between 300 and 500 square feet per gallon per coat on the first coat depending on porosity of surface. Subsequent coats or low porosity surfaces may yield higher coverage rates of 500-800 square feet per gallon.

 

Before application of sealer, make sure surface is free from dirt, oils, previous sealers, etc. It must be applied in thin coats. Two coats are usually sufficient, but applicator must determine the specific need. Sealer should be applied between 40 and 90 degrees Fahrenheit.

 

After applying the first coat, wait until the sealer is dry to the touch, usually 45 to 180 minutes for matte, 3-6 hours for gloss, depending on temperature and air flow, and then subsequent coats may be applied. Subsequent coats typically take 3 to 8 hours to dry for matte and 6 to 24 hours for gloss depending on temperature and air flow.

 

After application, tools may be cleaned using soap and water.

 

Light traffic is possible after 8-24 hours and heavy traffic is possible after 24-48 hours. The sealer will gain strength over the next few days after application and will reach full cure at 7-10 days. Avoid subjecting the sealer to freezing temperatures or moisture for 12-36 hours after application. Make sure substrate is dry before application.

 

ENDURABLE CONCRETE STAIN can penetrate product for the first 4 hours after sealer is dry when stain is mixed in water.

 

ENDURABLE CONCRETE STAIN may penetrate product when mixed in acetone for the first two days after application. If applying stain mixed in acetone over sealer, spray VERY lightly. Too much acetone can “cook” the sealer. Upon further curing, the stain cannot penetrate unless an additional coat of product is applied.

 

Only ENDURABLE VERTICAL STRIPPER may remove products when sealer is fully cured. This requires the stripper to be covered and remain wet for a minimum of 12 to 24 hours.

 

SLIP RESISTANCE AND CLEANABILITY: The profile of the concrete will dramatically affect the slip-resistance. Aggressive finishes, such as broom-finished concrete, will yield the best coefficient of friction and will be slightly more challenging to clean. Smooth surfaces will yield a lower coefficient of friction but are easier to clean. If desired, additional slip resistance can be added to the sealer. 100 mesh polypropylene will work well and should be applied in the second coat. It is best to mix it into the sealer and then apply with a T-Bar or the additive can be broadcast into the sealer. When slip-resistant additive is used, it is recommended to mix the sealer 1 to 1 with water to help keep the additive in solution. It is also recommended to apply a third coat of sealer to completely encompass and protect the additive.

Technical Specifications

Prop 65 This product can expose you to chemicals including Methanol which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Material Concrete
Category Cures\Sealers\Repellants
Brand Endurable
VOC Level Low
Type Liquid
Condition new
solids (%) 100

Documents

Real-World Knowledge Resource Center

  • Sign up for classes and training opportunities online or at a branch near you
  • Check out free how-to articles and technical tips prepared by our experts
  • Read our blog for the latest industry updates
See upcoming Webinars
Gain Real-World Knowledge